2.1.3 Conettix D6600/D6100 Communications Receivers/Gateways
For the Conettix D6600 and D6100 Communications Receivers/Gateways, the date and time is configured manually using
either the Conettix D6200 Programming/Administration Software or the unit’s front panel keypad. These units do not
perform an automatic Daylight Saving Time adjustment.
2.1.4 D6500 Central Station Receivers
Manually configure the date and time using the Time Set toggle switch near the top of the MPU card. These units do not
perform an automatic Daylight Saving Time adjustment.
2.1.5 D6000 Central Station Receivers
Manually configure the date and time using the CLK/CAL toggle switch on the back of the display panel faceplate. These
units do not perform an automatic Daylight Saving Time adjustment.
2.1.6 D6412/D4412 Control Panels
Disable the Auto Adjust for Daylight Saving Time function. Instead, manually change the control panel’s internal time
using either RPS or [CMD][45] from the keypad.
When using keypad programming to disable Daylight Saving Time, do not accidentally disable
keypad programming too.
2.1.7 D2012/D2112/D2212/D2012U/D2412/D2412U/D2812/D2812U Control Panels
These control panels are not affected by the new Daylight Saving Time rules because they do not contain an internal clock or
calendar.
2.1.8 D4112/D6112 Control Panels
These control panels are not affected by the new Daylight Saving Time rules because they do not contain an internal clock or
calendar.
2.1.9 D7112 Control Panels
These control panels do not provide an option for automatic Daylight Saving Time adjustment. Manually change the control
panel’s internal time using [CMD][45] from the keypad.
2.1.10 DS7060/DS7080i Series/DS7090/DS7090i/DS7090TM/DS7090TMi/
DS7100/DS7400 Series Control Panels
These control panels do not provide an option for automatic Daylight Saving Time adjustment. If the control panel connects
to WDSRP software, enable WDSRP’s Set Time Automatically function (located in Utilities → System Preferences). For
control panels configured to connect automatically to WDSRP, the time corrects upon establishing the first connection after
the time change.
2.1.11 D8112 Series Control Panels
These control panels do not provide an option for automatic Daylight Saving Time adjustment. Manually change the control
panel’s internal time using [CMD][45] from the keypad.
2.1.12 Safecom
®
SC9000/SC9001 Central Station Computers with ST1000 Software
The SC9000 and SC9001 are DOS PCs running ST1000 software. Use the ST1000 software to manually adjust the time and
date.
2.1.13 Safecom
®
SC4000/SC3100/SC2104 Radio Communicators
These radio communicators are not affected by the new Daylight Saving Time rules because they do not contain an internal
clock or calendar.